Pasadena, MD Air Conditioning, Heating and Plumbing Services

Home / Pasadena, MD Air Conditioning, Heating and Plumbing Services

Pasadena, MD Air Conditioning, Heating and Plumbing Services

Supreme Air provides Air Conditioning, Heating and Plumbing Services, Repair, Installation, Maintenance, and Tune Up in Pasadena, MD and surrounding areas.

Check out what some of our customers are saying about Supreme Air.

Local Reviews
for Pasadena, MD

Supreme Air Rated 5.0 out of 5 stars based on 1 customer reviews

Map of Pasadena, MD

Great service tech. Real gentleman.




Review of Supreme Air

Excellent


Youssef  D.

Youssef D.

On arrival found system not operating,found bad cap,i then replaced it and added hard start kit.unit came back on ,checked pressures ,unit operating normal

Near Swift Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

customer was not home didnt answer phones several attempts made within the time frame // text, phone calls, to no avail yonas left a note for customer to call the office and reschedule because he went to the home and there was no answer at the door

Near Creek Rd, Pasadena, MD 21122
Youssef  D.

Youssef D.

Water leaking from the pump assembly. May need to have it replaced.

Near Park Ln, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival set thermostat to call for cooling. Measured return temperature, supply temperature, amps,and voltage. Measured EWP,LWP,EWT, and LWT. I pressurized system to 60psi. Inspected electrical connections, contactor, blower wheel is clean,replaced filter provided by customer, tested condensate pump, cleaned condensate pan as well as the condensate drain line. Measured voltage absorption system rated for 80mfd. Actual reading 80.06mfd. I found dirty evaporator coil. Customer approved quote to clean evaporator coil. $284.75 Credit card payment. Customer renewed service agreement $299.00 credit card payment. Customer paid total of $583.75. I also recommended to get their duct cleaning, they will contact the office to schedule an appointment. Estimate for duct cleaning $521.90. Unit operating correctly at this time.

Near Poplar Ridge Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I went to system and shut off power. Removed old zoning panel and installed new one. Then replaced each thermostat. Finished installation by wiring in Humidistat. Returned power to system and tested heat and ac on all zones. Verified normal operation of HeatPump, Zone Panel, Thermoatats, and Dampers. Showed customer how to operate system. Unit operating normal at this time. Per office, customer prepaid for service.

Near Royal Beach Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I found main floor system heating, informed customer that when switching modes to make sure the unit “beeps” and matches the correct temperature on the display as the remote. Verified normal operation once system switched over from heat to ac. All units operating normal. Also showed customer how to adjust vane and fan speeds.

Near Harlem Rd, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I went to each AHU and turned off by remote. Went to condenser and removed disconnect. Replaced all black 3 pole switches with white ones. Verified tight connections. Returned power to system and tested each AHU individually. Units operating normal at this time.

Near Harlem Rd, Pasadena, MD 21122
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival set unit to call for cooling. Measured return temperature, supply temperature, EWP,LWP,EWT,LWT,amps, and voltage. Inspected electrical connections, contactor is ok, filter needs to be replace, blower wheel is clean, evaporator coil is clean, cleaned condensate drain line, and condensate pan. Unit is operating normal at this time.

Near Woodland Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

Spring Pm on 04/22/19 On arrival set units to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and replaced checked EWP and LWP and temp water pressure is low and high water temp I pump water pressure to 48/42 psi the temp is becoming cooler also checked compressor capacitor is good units tested units operating normal at this time.

Near Poplar Ridge Rd, Pasadena, MD 21122
Youssef  D.

Youssef D.

Repaired the refrigerant leak. Put system into a vacuum. Weighted in 410a refrigerant change. Checked operation.

Near Southwood Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

Service on 04/15/19 On arrival set units operating in both heating and cooling modes measured supply and return air temp measured voltage and amps all other electrical connections GEO and HEAT PUMP checked air filters is cleaned in cooling mode I checked the pressure and they’re ideal indicating zero leak in the system I checked water pressure for geo it was low pump it back up to 60/51 psi checked compressor and other electrical devices in the outdoor unit checked coil is cleaned checked capacitor is good I tested start up and unit began operating very smoothly with out hesitating or lag. Units operating normal at this time. Collected $328 on check #107 $199 for GEO tune Up and $129 heat pump 21tune up.

Near N Shore Rd, Pasadena, MD 21122
Derrick S.

Derrick S.

Install cust supplied vanity and faucet

Near Garden Rd, Pasadena, MD 21122
Yonas M.

Yonas M.

Tune Up special 04/11/19 On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and cleaned also checked condenser unit checked psi checked freon level checked electrical connections highly recommended customer has dust problem unit needs duct cleaning ASAP I gave quote for customer she don’t need it unit tested unit operating normal at this time. Collected $59 for tuneup special On C.C

Near 224th St, Pasadena, MD 21122
Youssef  D.

Youssef D.

On arrival set unit to call for cooling measured supply and return air temp measured voltage and amps inspected electrical connections checked water pressure,checked coils,checked drain and cleaned it .unit operating normal

Near Patapsco Rd, Pasadena, MD 21122
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measured temperature coming in and temperature going out, measured amps, and voltage. Inspected electrical connections, capacitor, contactor, blower wheel is clean, evaporator coil is clean, Replaced filter provided by customer, tested condensate pump, and cleaned condensate drain line. Customer renew service agreement, paid in full $199.92. Unit is operating normal at this time.

Near Creek Blvd, Pasadena, MD 21122
Youssef  D.

Youssef D.

on arrival noticed new intellizone2 won't work without a daughter board .need to order 17p855-01 and im1678ew .system is working at this time .

Near Royal Beach Rd, Pasadena, MD 21122
michaelr@supremeairllc.com

michaelr@supremeairllc.com

On arrival checked thermostat was calling for cooling. Measure temperature coming in and temperature going out, measure amps, voltage, EWT,LWT,EWP,LWP. Inspected blower wheel, evaporator coil, clean condensate line, contactor, electrical connections, and filter. Unit is operating normal at this time.

Near Holmewood Dr, Pasadena, MD 21122
Derrick S.

Derrick S.

Cust called and cancelled said they figured out the problem

Near Outing Ave, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I found Geo Cube in lockout condition. Reset and checked fault codes, FP1 sensor fault. Put gauges on system and checked charge along with loop pressure and temp drop. Found low discharge and suction pressure. Water flow looks to be in spec. When removing discharge cap I found pin was leaking. Quoted customer repair options and they chose adding 410a plus leak sealer. Added leak sealer then added refrigerant, about 1.3 lbs. Also tightened all pins. Checked Superheat and subcool. Checked delta air temp and amp draw. Unit operating normal at this time.

Near Park Ln, Pasadena, MD 21122
Colin T.

Colin T.

Upon arrival I spoke with customer and she explained that she was expecting us back today to perform maintenance. After speaking with customer she would like to hold off on replacing contactor. She mentioned that system didn’t turn on for her the other day when calling for heat. Found zoning panel not letting 2nd stage run, suspecting zoning panel wasn’t letting system run at all. Quoting customer to replace Intellizone Panel. Performed pm on Geo System. Filter is new. Flushed out drain with brush and hot water. Checked cleanliness of coil and blower. Checked electrical connections and inspected contactor and capacitor. Ran heat. Checked amp draw of compressor, blower, and loop pumps. Checked delta air temp at Evap coil. Checked delta loop pressures and temps. Unit is operating but only on 1st stage. Quoting customer to replace zone panel.

Near Royal Beach Rd, Pasadena, MD 21122
Christopher A.

Christopher A.

I operated the unit on second stage heating mode. I checked the electrical wiring and electrical systems, all are within specification. I decreased blower speed to 350 cfm per ton of capacity to increase the temperature rise. I checked the auxiliary heat strips. Flow rate cannot but adjusted but the heat of extraction is normal for 8psi pressure drop. The ground loop pressures are adequate. Unit operating normal. I highly recommended a start assist for the compressor and the customer agreed. I installed a hard start kit for 1-3hp compressors. I tested it to make sure it was working. Compressor starts much easier and quickly.

Near Park Ln, Pasadena, MD 21122
Yonas M.

Yonas M.

Fall pm on 01/14/18 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and replaced recommended to install de humidifier unit operating normal at this time.

Near List Ave, Pasadena, MD 21122
Yonas M.

Yonas M.

Fall pm on 01/14/18 On arrival set units to call for heat measured supply and return air temp measured voltage and amps inspected electrical connections checked drain and cleaned checked filters and replaced recommended to install de humidifier unit operating normal at this time.

Near List Ave, Pasadena, MD 21122
Yonas M.

Yonas M.

GEO water furnace fall pm severna Park MD

Near List Ave, Pasadena, MD 21122
Pasadena, MD - GEO water furnace fall pm severna Park MD
Youssef  D.

Youssef D.

When we arrived we found a clog water line from humidifier, we pressurized it with nitrogen to clean it. We left the house and water line was working correctly.

Near Poplar Ridge Rd, Pasadena, MD 21122