Westminster, MD Air Conditioning, Heating and Plumbing Services

Home / Westminster, MD Air Conditioning, Heating and Plumbing Services

Westminster, MD Air Conditioning, Heating and Plumbing Services

Supreme Air provides Air Conditioning, Heating and Plumbing Services, Repair, Installation, Maintenance, and Tune Up in Westminster, MD and surrounding areas.

Check out what some of our customers are saying about Supreme Air.

Local Reviews
for Westminster, MD


Youssef  D.

Youssef D.

On arrival set unit to call for cooling.found system has a leak .unit is 15 years old with r22 system .customer is getting an estimate to replace tomorrow.unit is not operating at this time . Warrantied per Darlene

Near W Sunshine Way, Westminster, MD 21157
Christopher A.

Christopher A.

Upstairs unit not operating outside because the voltage absorption system was open for the compressor. I replaced it with 40&5 uf dual run cap and tested the unit. Unit uses r22 refrigerant and the pressures were lower than normal. I went into the attic and had 87 return and 69 supply air temperature. I opened up the blower compartment and felt refrigerant oil inside of the evaporator drain pan. I spoke with the customer about this because it is cooling but most certainly has a leak in the coil. I had to make an estimate to replace the coil and document what I found to protect myself. Otherwise the unit is operating normal.

Near W Sunshine Way, Westminster, MD 21157
Youssef  D.

Youssef D.

On arrival set unit to call for cooling;found system was locked out on e3 low pressure 70 times .checked system pressures ok.checked Txv ok .checked sensors ok.noticed blower motor fluctuate a lot which is a sign of failure and could be the problem that causes unit to fault on e3 low pressure.unit is operating now but could stop any time .

Near Leppo Rd, Westminster, MD 21158
MarkM@supremeairllc.com

MarkM@supremeairllc.com

Completed the spring maintenance. Checked wiring and connections. Replaced the air filters. Cleaned drain pans and traps. Cleaned the condenser coils. Checked the blower belt. Checked unit operation.

Near Baltimore Blvd, Westminster, MD 21157
Daniel M.

Daniel M.

Clean coils and completed AC inspection .

Near Baltimore Blvd, Westminster, MD 21157
Daniel M.

Daniel M.

Found unit #3 with a black thermostat. Went on roof and found my transformer was receiving 210 volts and only putting out 8 volts . Replaced 208 volt 75 va transformer with one with a built in fuse and checked operations . System is operating properly

Near Baltimore Blvd, Westminster, MD 21157
Daniel M.

Daniel M.

Changed out filters and it started raining . Waited 30 minutes for rain to slow down or pass and it did not . Need to come back to complete maintenance 01-03-19 . Completed heating maintenance on systems

Near Baltimore Blvd, Westminster, MD 21157
Daniel M.

Daniel M.

Changed out filters and it started raining . Waited 30 minutes for rain to slow down or pass and it did not . Need to come back to complete maintenance

Near Baltimore Blvd, Westminster, MD 21157